AGS4800 Real-time
PCR Detection System

Product Introduction

PCR detection system is mainly composed of control system, power supply system, photoelectric system, module components, hot lid, shell parts and software etc. Its working principle is: to achieve reagent sample amplification by temperature control according to programmed parameters for sample denaturation under high temperature, annealing under low temperature and extension under optimum temperature, and to detect real-time fluorescence changes of samples through photoelectric system as well as analyze and process data detected by software.
Based on real-time fluorescence quantitative polymerase chain reaction technology, the product can be widely used in researches such as immunology, human genome engineering, forensic medicine, oncology, histology, population biology, palaeobiology, zoology and botany, and in clinical diagnosis of viruses, tumors and hereditary diseased, etc.

Highly Cost-effective Channel Combination, up to 6+2

Programming interface

AGS4800 Real-time PCR Detection System

Product Features

• High throughput up to 144 samples and flexible choices of detection systems (sample sizes: 48, 96 and 144 optional)
• 3 independent detection systems with samples loaded and analyzed independently or simultaneously
• Automatic sample inlet and outlet as well as automatic hot lid
• Wireless real-time remote control and analysis
• Positive detection rate analysis and early warning of laboratory pollution

Parametry techniczne

Real-time PCR Detection System
Model AGS4800
Capacity 3*48*0.2m1(10-100111 ), adaptive to 18*8 strip tubes
Detection system 3 independent detection systems
Light source LED
Detector High sensitivity photoelectric sensor
Sensitivity 1 copy (Min.)
Test dynamic range 10^0 -10^10
Reaction volume 5-100ml
Fluorescence and dyes Fl: FAM, SYBR GREEN
F2: VIC, HEX, JOE, TET, YELLOW
F3: CY3, F4: ROX, F5: CY5, F6: CY5.5
F7: Reserved, F8: Reserved
Hot-lid Automatic
Temperature range 4-100°C
Temperature-control pattern Semiconductor TE module
Temperature uniformity ±0.1°C
Precision of temperature control ±0.1°C
Ramp-up rate >6.5°C/s
Ramp-down rate >6.5°C/s
Hot-lid temperature range 30-110°C
Fluorescent intensity detection CV <0.5%
Sample linearity Linear regression coefficient > 0.999
Communication Interface USB 2.0
Operating system Windows Vista/7/8/10
Input power 100-240V, 50/60Hz, 500-1500VA
Certification CFDA, CE
Dimension (L*W*H) 586mm x 526mm x 780mm